Local Config via USB
Configure your Lobaro device locally using the USB Config Adapter and the Lobaro Config Tool.
-
Connect the USB Config Adapter to your device's CONFIG port and to your PC via USB.
noteThe adapter does not power the device. Always supply external power.
-
Open the Lobaro Config Tool in your browser (
http://localhost:8585), select the port (or use auto) and click Connect. -
Go to the CONFIGURATION tab and click Reload Config to read the current parameters.
-
Edit the desired parameters (changed values appear in bold), then click Write to Device to apply them.
warningWrite to Device reboots the device. Always reload the config before editing when switching between devices.
-
Verify the new configuration in the LOGS tab after the reboot.
For firmware updates via USB, see Firmware Update — Local via USB.