CARMEN DSP Configuration
The CARMEN DSP Add-On reads pressure and temperature values from an Endress+Hauser CARMEN sensor via its DSP interface (UART).
Compatible product: Gateway V4 + CARMEN DSP
Configuration Parameters
In addition to the GW4 configuration parameters the add-on has the following specific parameters:
CARMEN DSP Reading
| Key | Type | Factory setting | Description |
|---|---|---|---|
carmenUartSpeed | Number | 57600 | Data rate of the UART to the CARMEN DSP (8N1, no hardware flow control). Cannot be changed by the user at the moment |
carmenCommand | String | soft_reset,read_typeplate,soft_reset,read_frame,stop_dsp | Comma-separated list of DSP commands executed at startup |
Parameter reference in preparation
The complete parameter reference for the CARMEN DSP add-on is being prepared. The parameters listed above are the values configured in production.